Abstract The fouling of the membrane severely reduces the efficiency of the RO system, so membrane cleaning is required if the water flux is reduced. To solve this problem��researchers are focusing on the precise prediction of the membrane fouling��real��time monitoring��analysis of the pollution species and efficiency methods to control the pollution. In this paper��wastewater treatment system of PetroChina Dushanzi Petrochemical Company is comprehensively investigated to analyze the membrane structure, methods of monitoring and controlling the membrane fouling. An efficient way is proposed to precisely predict the membrane fouling and effectively control the pollution. It is hopefully that the current work would give reference to the similar equipments.
LV Hui , WANG Wei, HE Li-Li.Monitoring and Controlling of Membrane Fouling in Reverse Osmosis[J] Chemcial Industry and Engineering, 2010,V27(6): 525-529