Abstract Quad orthogonal test was used to optimize the condition for hydrogenation of residual C_5.Necessary experiments had been done based on the table of quad orthogonal experiment with four factors,such as pressure,ratio of hydrogen to pentene,inlet temperature and gas velocity of liquid,at five levels.The mathematical model on the relationship among the four factors and total conversion of pentenes had been set up according to the experiment data,the model was proved reasonable by comparing the experimental data and the calculating data.The optimum condition of residual C_5 hydrogenation had been found.
MA Hong-xi,XIE Jia-ming,CHEN Li-hua.Quad Orthogonal Test in Optimizing the Hydrogenation of Pentene[J] Chemcial Industry and Engineering, 2005,V22(1): 24-27