Gas-Agitated Liquid-Liquid Extraction of Hydrogen Peroxide
LIU Chuan-qiang~1,MA Zhong-long~2,JIANG Shao-kun~1,LIU Jian-guo~1(1.State Key Laboratory of Chemical Engineering,School of Chemical Engineering and Technology,Tianjin University,Tianjin 300072,China;2.Tianjin Lishen Battery Joint-Stock Co.,Ltd.,Tianjin 300384,China)
(1.State Key Laboratory of Chemical Engineering,School of Chemical Engineering and Technology,Tianjin University,Tianjin 300072,China;2.Tianjin Lishen Battery Joint-Stock Co.,Ltd.,Tianjin 300384,China

Abstract
Reference
Related Articles
Download: PDF (307KB)   HTML 1KB   Export: BibTeX or EndNote (RIS)      Supporting Info
Abstract In a plate column with diameter of 50 mm,the process of gas-agitation extraction about anthraquinone working solution-H_2O_2-H_2O system has been studied.The system temperature maintained at 40 ��.The air superfacial velocity was 0��3.22 mm/s and the disperse phase superficial velocity was 1.27��1.70 mm/s.The superficial flow ratio of dispersed phase to continuous phase was maintained at 50��1.The experimental result showed that the overall plate extraction efficiency of gas-agitated plate column is obviously higher than that of conventional plate column,disperse phase hold-up increased and the content of hydrogen peroxide in residual extraction decreased.
Service
Email this article
Add to my bookshelf
Add to citation manager
Email Alert
RSS
Articles by authors
Keywords��   
Received 2006-09-15; published 2006-09-15
Cite this article:   
LIU Chuan-qiang~1,MA Zhong-long~2,JIANG Shao-kun~1,LIU Jian-guo~1.Gas-Agitated Liquid-Liquid Extraction of Hydrogen Peroxide[J]  Chemcial Industry and Engineering, 2006,V23(5): 411-414
Copyright 2010 by Chemcial Industry and Engineering