A Study of Exactitude in Diffusivity Measurements by Higbie��s Penetration Theory
Xu Yingnong

Abstract
Reference
Related Articles
Download: PDF (0KB)   HTML 0KB   Export: BibTeX or EndNote (RIS)      Supporting Info
Abstract A wetted column was used to measure the rate of absorption of carbon dioxide in aqueous polymer solutions.The experimental results showed that the exactitude in diffusivity calculation by Higbie��s penetration theory can be ensured when dimensionless contact time t<0.1.
Service
Email this article
Add to my bookshelf
Add to citation manager
Email Alert
RSS
Articles by authors
Keywords�� s:diffusivity;exactitude;penetration theory;dimensionless contact time     
Received 1995-04-15;
Cite this article:   
Xu Yingnong.A Study of Exactitude in Diffusivity Measurements by Higbie��s Penetration Theory[J]  Chemcial Industry and Engineering, 1995,V12(2): 46-48