化学工业与工程
Home  |   |  About Journal  |  Editorial Board  |  Instruction  |  Subscriptions  |  Download  |  Publication Ethics  |  Contacts Us  |  Chinese
Chemcial Industry and Engineering 1995, Vol. 12 Issue (3) :59-63    DOI:
Article Current Issue | Next Issue | Archive | Adv Search << | >>
Modification of Determination for Frictional Pressure Drop of Gas-Liquid Two-Phase Up-Flow in Vertical Tube
Hu Ruijie;Chen Yuanming ;Chen Yonghui

Abstract
Reference
Related Articles
Download: PDF (0KB)   HTML 0KB   Export: BibTeX or EndNote (RIS)      Supporting Info
Abstract The frictional pressure drop of gas-liquid two-phase up-flow in vertical tube has been investigeted.The technigue of measurement of differential pressure and holdup have been improved.The flow patterns were determined by visual observation. Experiments were carried out with air and water in a vertical glass tube of 19mm inside diameter and 1500mm height. The values of frictional pressure drop were calculated from experiment data of differential pressure and holdup.
Service
Email this article
Add to my bookshelf
Add to citation manager
Email Alert
RSS
Articles by authors
Keywords�� s: gas-liquid two phase flow;pressure drop; holdup     
Received 1995-07-15;
Cite this article:   
Hu Ruijie;Chen Yuanming ;Chen Yonghui.Modification of Determination for Frictional Pressure Drop of Gas-Liquid Two-Phase Up-Flow in Vertical Tube[J]  Chemcial Industry and Engineering, 1995,V12(3): 59-63