[an error occurred while processing this directive]
化学工业与工程
 首页 |  在线投稿 |  期刊介绍 |  编 委 会 |  投稿指南 |  期刊订阅 |  下载中心 |  出版伦理 |  联系我们 |  English
化学工业与工程 2014, Vol. 31 Issue (6) :24-28    DOI: doi: 10.13353/j.issn.1004.9533.2014.06.005
过程与设备 最新目录 | 下期目录 | 过刊浏览 | 高级检索 << | >>
数字全息法测量液相扩散系数实验研究
周密,张亚辉,袁希钢
化学工程联合国家重点实验室,天津大学化工学院,天津 300072
Diffusivity Measurement of Liquid Solutions by Real-Time Digital Holography
ZHOU  Mi, ZHANG  Ya-Hui, YUAN  Xi-Gang
State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072,China

摘要
参考文献
相关文章
Download: PDF (873KB)   HTML ()   Export: BibTeX or EndNote (RIS)      Supporting Info
摘要 采用数字全息干涉法测量了25 ℃乙二醇-水物系的扩散系数。详细介绍了实验方法以及2种处理干涉图像获得扩散系数的方法,即横条纹法和弯条纹法。通过测量25 ℃时0.33 mol/L KCl溶液的扩散验证了实验的精确性。分别用2种方法获得了6个不同质量分数下的乙二醇-水物系的扩散系数,并与文献值进行了对比。结果表明,弯曲条纹法的平均相对偏差是1.3%,比水平条纹法的1.7%小,同时,弯曲条纹法的平均标准偏差更小,说明波动更小。
Service
把本文推荐给朋友
加入我的书架
加入引用管理器
Email Alert
RSS
作者相关文章
周密
张亚辉
袁希钢
关键词数字全息;   扩散系数;   干涉条纹     
Abstract: Real-Time digital holography is used to measure the diffusivities of ethylene glycol-water system at 25 ℃. The experimental technique and two methods based on horizontal and curved fringes for processing holographic image data are presented in detail. 0.33 mol·L-1 aqueous solution of potassium chloride at 25 ℃ was used as a reference system to check the two methods. Compared with literature data, the results show that both methods are reliable with good accuracy. Measurements are conducted at 6 concentrations of the ethylene glycol-water system and the results of both methods are also compared with the reported data. The average relative deviation of the curved fringe method is 1.3%, slightly superior to that of the horizontal fringes method. Moreover,diffusivities calculated by the two methods fluctuate with the choice of time. A comparison of the standard deviations of the two methods shows that the curved fringe method is more stable than the horizontal fringe method.
Keywordsdigital holography;   diffusion coefficient;   fringe pattern     
Received 2013-04-17;
Fund:

国家自然科学基金(20736005)。

Corresponding Authors: 袁希钢,电话:(022)27402786,E-mail: yuanxg@tju.edu.cn。     Email: yuanxg@tju.edu.cn
About author: 周密(1989-),男,硕士生,主要研究扩散传质。
引用本文:   
周密, 张亚辉, 袁希钢.数字全息法测量液相扩散系数实验研究[J].  化学工业与工程, 2014,31(6): 24-28
ZHOU Mi, ZHANG Ya-Hui, YUAN Xi-Gang.Diffusivity Measurement of Liquid Solutions by Real-Time Digital Holography[J].  Chemcial Industry and Engineering, 2014,31(6): 24-28
Copyright 2010 by 化学工业与工程